Autoclima - Post@autoclima.no - Tel: 23 17 75 70
ELECTRONIC LEAK DETECTOR - REFRIGERANTS AND FLAMMABLE GASES
ELECTRONIC LEAK DETECTOR - REFRIGERANTS AND FLAMMABLE GASES
Intellasense 55800 – Electronic leak detector for refrigerants and flammable gases
A highly sensitive leak detector for professional use
The Mastercool Intellasense 55800 is an advanced leak detector designed to detect even the smallest amounts of refrigerants and flammable gases. It uses a newly developed metal oxide sensor with high sensitivity and lightning-fast response. An integrated microprocessor optimizes the sensor's performance in real time, ensuring reliable detection under all conditions. Approved according to SAE J2791 (R134a), J2913 (R1234yf) and EN 14624.
Specifications
Detects:
-
CFC, HCFC and HFC refrigerants
-
R1234yf, R32, R410A
-
Hydrogen
-
Flammable gases
Sensitivity levels:
-
High: ≥ 4.25 g/yr (0.15 oz/yr)
-
Medium: ≥ 7 g/yr (0.25 oz/yr)
-
Low: ≥ 14 g/yr (0.5 oz/yr)
Technical information:
-
Sensor life: approximately 2000 hours
-
Operating temperature: –18 °C to +60 °C
-
Power: 2 x D batteries (included)
-
Battery life: approximately 60 hours of continuous use
-
Weight: 680g
Probe:
-
39.5 cm flexible probe
-
Intelligent tip that minimizes false alarms
Display and indicators
-
LCD display with 10 level indicators
-
Shows selected sensitivity level
-
Low battery warning
-
Status display: “READY”, “WAIT”, “INT”
-
Error codes E1–E9
Functions and operation
-
Automatic sensor optimization in real time
-
“Super Sensitive” mode for very small leaks
Keys:
-
ON/OFF: Turn the device on/off
-
VOLUME/MUTE: Adjust or mute sound
-
H/M/L: Select sensitivity level
-
HOLD: Freeze leak level display
-
PEAK: Detect multiple leaks simultaneously
Couldn't load pickup availability