{"product_id":"vakumpumpe-170l-min-2-stegs-black-series","title":"VACUUM PUMP 170l\/min - 2-STAGE - BLACK SERIES","description":"\u003ch2 data-start=\"232\" data-end=\"304\"\u003e 90066-220-BLSF Black Series Spark-Free Vacuum Pump 170 L\/min – 2-Stage\u003c\/h2\u003e\n\n\u003cp data-start=\"306\" data-end=\"596\"\u003e \u003cstrong data-start=\"306\" data-end=\"352\"\u003eProfessional spark-free 2-stage vacuum pump\u003c\/strong\u003e from Mastercool Black Series, \u003cstrong data-start=\"382\" data-end=\"421\"\u003eapproved for all types of refrigerants\u003c\/strong\u003e , including \u003cstrong data-start=\"433\" data-end=\"468\"\u003eA2L and A3 flammable refrigerants\u003c\/strong\u003e . Developed for demanding applications in \u003cstrong data-start=\"503\" data-end=\"539\"\u003eAC service, AC charging and HVAC\u003c\/strong\u003e , where safety, performance and reliability are essential.\u003c\/p\u003e\n\n\u003chr data-start=\"598\" data-end=\"601\"\u003e\n\n\u003ch3 data-start=\"603\" data-end=\"625\"\u003e Product description\u003c\/h3\u003e\n\n \u003cp data-start=\"627\" data-end=\"966\"\u003eThe Mastercool 90066-220-BLSF is a powerful, high capacity \u003cstrong data-start=\"667\" data-end=\"704\"\u003espark free vacuum pump\u003c\/strong\u003e , specifically designed for working with both traditional and flammable refrigerants. The pump combines high vacuum performance with improved internal oil flow and precision machining, resulting in lower operating temperatures, reduced wear and longer service life.\u003c\/p\u003e\n\n\u003cp data-start=\"968\" data-end=\"1191\"\u003e The thermally protected motor, together with the gas ballast valve and check valve, ensures stable and safe operation even under demanding conditions. The manifold valve allows the pump to be isolated from the system during leak testing.\u003c\/p\u003e\n\n\u003chr data-start=\"1193\" data-end=\"1196\"\u003e\n\n\u003ch3 data-start=\"1198\" data-end=\"1212\"\u003e Features \u003c\/h3\u003e\n\n\u003cul data-start=\"1214\" data-end=\"2024\"\u003e\n\n\u003cli data-start=\"1214\" data-end=\"1290\"\u003e\n\n\u003cp data-start=\"1216\" data-end=\"1290\"\u003e \u003cstrong data-start=\"1216\" data-end=\"1241\"\u003eSpark Free\u003c\/strong\u003e – approved for A2L and A3 flammable refrigerants \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1291\" data-end=\"1335\"\u003e\n\n\u003cp data-start=\"1293\" data-end=\"1335\"\u003e Refined machining provides longer service life \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1336\" data-end=\"1394\"\u003e\n\n\u003cp data-start=\"1338\" data-end=\"1394\"\u003e Improved internal oil flow reduces friction and heat \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1395\" data-end=\"1446\"\u003e\n\n\u003cp data-start=\"1397\" data-end=\"1446\"\u003e Upgraded seals for maximum vacuum performance \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1447\" data-end=\"1475\"\u003e\n\n\u003cp data-start=\"1449\" data-end=\"1475\"\u003e Developed and tested in the USA \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1476\" data-end=\"1502\"\u003e\n\n\u003cp data-start=\"1478\" data-end=\"1502\"\u003e Ergonomic carrying handle \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1503\" data-end=\"1569\"\u003e\n\n\u003cp data-start=\"1505\" data-end=\"1569\"\u003e Gas ballast valve reduces oil contamination in high humidity conditions\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1570\" data-end=\"1616\"\u003e\n\n \u003cp data-start=\"1572\" data-end=\"1616\"\u003eRemovable steam outlet and oil fill port \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1617\" data-end=\"1667\"\u003e\n\n\u003cp data-start=\"1619\" data-end=\"1667\"\u003e Large oil level inspection glass (min\/max) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1668\" data-end=\"1705\"\u003e\n\n\u003cp data-start=\"1670\" data-end=\"1705\"\u003e Easily accessible oil drain valve \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1706\" data-end=\"1750\"\u003e\n\n\u003cp data-start=\"1708\" data-end=\"1750\"\u003e Thermally protected motor with on\/off switch \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1751\" data-end=\"1839\"\u003e\n\n\u003cp data-start=\"1753\" data-end=\"1793\"\u003e Manifold valve with \u003cstrong data-start=\"1772\" data-end=\"1790\"\u003e3 connections\u003c\/strong\u003e : \u003c\/p\u003e\n\n\u003cul data-start=\"1796\" data-end=\"1839\"\u003e\n\n\u003cli data-start=\"1796\" data-end=\"1808\"\u003e\n\n\u003cp data-start=\"1798\" data-end=\"1808\"\u003e 1\/4″ SAE \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1811\" data-end=\"1823\"\u003e\n\n\u003cp data-start=\"1813\" data-end=\"1823\"\u003e 3\/8″ SAE \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1826\" data-end=\"1839\"\u003e\n\n\u003cp data-start=\"1828\" data-end=\"1839\"\u003e 1\/2″ ACME \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1840\" data-end=\"1909\"\u003e\n\n\u003cp data-start=\"1842\" data-end=\"1909\"\u003e Check valve prevents oil from flowing back into the system \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1910\" data-end=\"1966\"\u003e\n\n\u003cp data-start=\"1912\" data-end=\"1966\"\u003e High-volume cooling fan and heatsinks for stable operation \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1967\" data-end=\"2024\"\u003e\n\n\u003cp data-start=\"1969\" data-end=\"2024\"\u003e Lightweight and reinforced base for secure and stable placement \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"2026\" data-end=\"2029\"\u003e\n\n\u003ch3 data-start=\"2031\" data-end=\"2059\"\u003e Technical specifications \u003c\/h3\u003e\n\n\u003cul data-start=\"2061\" data-end=\"2404\"\u003e\n\n\u003cli data-start=\"2061\" data-end=\"2084\"\u003e\n\n\u003cp data-start=\"2063\" data-end=\"2084\"\u003e \u003cstrong data-start=\"2063\" data-end=\"2080\"\u003eNumber of steps:\u003c\/strong\u003e 2 \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2085\" data-end=\"2168\"\u003e\n\n\u003cp data-start=\"2087\" data-end=\"2120\"\u003e \u003cstrong data-start=\"2087\" data-end=\"2118\"\u003eCapacity (free airflow):\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"2123\" data-end=\"2168\"\u003e\n\n\u003cli data-start=\"2123\" data-end=\"2144\"\u003e\n\n\u003cp data-start=\"2125\" data-end=\"2144\"\u003e 170 l\/min (60 Hz) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2147\" data-end=\"2168\"\u003e\n\n\u003cp data-start=\"2149\" data-end=\"2168\"\u003e 142 l\/min (50 Hz) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2169\" data-end=\"2199\"\u003e\n\n\u003cp data-start=\"2171\" data-end=\"2199\"\u003e \u003cstrong data-start=\"2171\" data-end=\"2187\"\u003eFinal vacuum:\u003c\/strong\u003e 15 microns \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2200\" data-end=\"2221\"\u003e\n\n\u003cp data-start=\"2202\" data-end=\"2221\"\u003e \u003cstrong data-start=\"2202\" data-end=\"2212\"\u003eEngine:\u003c\/strong\u003e 1\/2 HP \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2222\" data-end=\"2247\"\u003e\n\n\u003cp data-start=\"2224\" data-end=\"2247\"\u003e \u003cstrong data-start=\"2224\" data-end=\"2236\"\u003eSpeed:\u003c\/strong\u003e 1440 RPM \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2248\" data-end=\"2271\"\u003e\n\n\u003cp data-start=\"2250\" data-end=\"2271\"\u003e \u003cstrong data-start=\"2250\" data-end=\"2263\"\u003eVoltage:\u003c\/strong\u003e 220V \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2272\" data-end=\"2300\"\u003e\n\n\u003cp data-start=\"2274\" data-end=\"2300\"\u003e \u003cstrong data-start=\"2274\" data-end=\"2287\"\u003eFrequency:\u003c\/strong\u003e 50 \/ 60 Hz\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2301\" data-end=\"2338\"\u003e\n\n \u003cp data-start=\"2303\" data-end=\"2338\"\u003e\u003cstrong data-start=\"2303\" data-end=\"2323\"\u003ePower connection:\u003c\/strong\u003e 220 V schuko \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2339\" data-end=\"2361\"\u003e\n\n\u003cp data-start=\"2341\" data-end=\"2361\"\u003e \u003cstrong data-start=\"2341\" data-end=\"2350\"\u003eWeight:\u003c\/strong\u003e 11.22 kg \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2362\" data-end=\"2404\"\u003e\n\n\u003cp data-start=\"2364\" data-end=\"2404\"\u003e \u003cstrong data-start=\"2364\" data-end=\"2380\"\u003eDimensions:\u003c\/strong\u003e 37.9 × 16.7 × 27.5 cm \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"2406\" data-end=\"2409\"\u003e\n\n\u003ch3 data-start=\"2411\" data-end=\"2433\"\u003e Service information \u003c\/h3\u003e\n\n\u003cul data-start=\"2435\" data-end=\"2464\"\u003e\n\n\u003cli data-start=\"2435\" data-end=\"2464\"\u003e\n\n\u003cp data-start=\"2437\" data-end=\"2464\"\u003e \u003cstrong data-start=\"2437\" data-end=\"2455\"\u003eOil capacity:\u003c\/strong\u003e 440 ml\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"2466\" data-end=\"2574\"\u003e * Note: Micron value stated is measured under optimal laboratory conditions. Actual values ​​may vary in the field.\u003c\/p\u003e\n\n\u003chr data-start=\"2576\" data-end=\"2579\"\u003e\n\n\u003ch3 data-start=\"2581\" data-end=\"2596\"\u003e Application\u003c\/h3\u003e\n\n\u003cp data-start=\"2598\" data-end=\"2608\"\u003e Suitable for: \u003c\/p\u003e\n\n\u003cul data-start=\"2609\" data-end=\"2825\"\u003e\n\n\u003cli data-start=\"2609\" data-end=\"2639\"\u003e\n\n\u003cp data-start=\"2611\" data-end=\"2639\"\u003e AC service and AC refill \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2640\" data-end=\"2670\"\u003e\n\n\u003cp data-start=\"2642\" data-end=\"2670\"\u003e Vacuuming of air conditioners \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2671\" data-end=\"2707\"\u003e\n\n\u003cp data-start=\"2673\" data-end=\"2707\"\u003e HVAC installation and maintenance \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2708\" data-end=\"2758\"\u003e\n\n\u003cp data-start=\"2710\" data-end=\"2758\"\u003e Working with \u003cstrong data-start=\"2721\" data-end=\"2756\"\u003eA2L and A3 flammable refrigerants\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2759\" data-end=\"2825\"\u003e\n\n\u003cp data-start=\"2761\" data-end=\"2825\"\u003e Professional workshops and service vehicles with high safety requirements\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Min butikk","offers":[{"title":"Default Title","offer_id":51704320590125,"sku":"9066","price":6800.0,"currency_code":"NOK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0932\/4668\/5485\/files\/90066-220-BLSF-web.jpg?v=1766273528","url":"https:\/\/shop.autoclima.no\/en\/products\/vakumpumpe-170l-min-2-stegs-black-series","provider":"Autoclima AS","version":"1.0","type":"link"}