{"product_id":"nitrogenregulator-mastercool","title":"Nitrogen regulator - Mastercool","description":"\u003ch2 data-start=\"163\" data-end=\"200\"\u003e Mastercool Nitrogen Pressure regulator\u003c\/h2\u003e\n\n \u003cp data-start=\"202\" data-end=\"552\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eMastercool\u003c\/span\u003e\u003c\/span\u003e 's nitrogen pressure regulator is specifically designed for \u003cstrong data-start=\"293\" data-end=\"349\"\u003eleak testing of HVAC\/R and automotive AC systems\u003c\/strong\u003e when the system \u003cstrong data-start=\"363\" data-end=\"394\"\u003edoes not contain refrigerant\u003c\/strong\u003e . The regulator is a \u003cstrong data-start=\"414\" data-end=\"446\"\u003esingle-stage nitrogen regulator\u003c\/strong\u003e that allows the system to be pressurized with inert nitrogen gas for fast, safe and efficient leak detection.\u003c\/p\u003e\n\n\u003cp data-start=\"554\" data-end=\"733\"\u003e This is a time-saving and cost-effective tool for professional technicians who want to test systems without the use of refrigerant, UV dye or electronic leak detectors.\u003c\/p\u003e\n\n\u003chr data-start=\"735\" data-end=\"738\"\u003e\n\n\u003ch3 data-start=\"740\" data-end=\"785\"\u003e Effective leak testing without refrigerant\u003c\/h3\u003e\n\n \u003cp data-start=\"787\" data-end=\"996\"\u003eBy pressurizing an empty system with nitrogen, leaks can be located quickly and precisely. Once the test is complete, the valve insert is easily removed to release the inert nitrogen gas in a controlled manner.\u003c\/p\u003e\n\n\u003cp data-start=\"998\" data-end=\"1136\"\u003e The regulator can be used on \u003cstrong data-start=\"1024\" data-end=\"1073\"\u003eall applications requiring a 1\/4\" connection\u003c\/strong\u003e , including HVAC systems and refrigeration systems for R12, R22 and R134a.\u003c\/p\u003e\n\n\u003chr data-start=\"1138\" data-end=\"1141\"\u003e\n\n\u003ch3 data-start=\"1143\" data-end=\"1155\"\u003e Benefits \u003c\/h3\u003e\n\n\u003cul data-start=\"1157\" data-end=\"1435\"\u003e\n\n\u003cli data-start=\"1157\" data-end=\"1225\"\u003e\n\n\u003cp data-start=\"1159\" data-end=\"1225\"\u003e \u003cstrong data-start=\"1159\" data-end=\"1193\"\u003eTime-saving leak testing\u003c\/strong\u003e – no need for refrigerant \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1226\" data-end=\"1289\"\u003e\n\n\u003cp data-start=\"1228\" data-end=\"1289\"\u003e \u003cstrong data-start=\"1228\" data-end=\"1259\"\u003eNo recovery required\u003c\/strong\u003e – system is pressurized empty \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1290\" data-end=\"1334\"\u003e\n\n\u003cp data-start=\"1292\" data-end=\"1334\"\u003e Easy emptying by removing the valve insert \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1335\" data-end=\"1398\"\u003e\n\n\u003cp data-start=\"1337\" data-end=\"1398\"\u003e Can be used on a wide range of HVAC and AC applications \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1399\" data-end=\"1435\"\u003e\n\n\u003cp data-start=\"1401\" data-end=\"1435\"\u003e Precise and stable pressure regulation \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"1437\" data-end=\"1440\"\u003e\n\n\u003ch3 data-start=\"1442\" data-end=\"1470\"\u003e Technical specifications \u003c\/h3\u003e\n\n\u003cul data-start=\"1472\" data-end=\"1789\"\u003e\n\n\u003cli data-start=\"1472\" data-end=\"1498\"\u003e\n\n\u003cp data-start=\"1474\" data-end=\"1498\"\u003e Output: 1\/4\" SAE flare \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1499\" data-end=\"1566\"\u003e\n\n\u003cp data-start=\"1501\" data-end=\"1566\"\u003e Equipped with control valve for constant pressure on the regulator \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1567\" data-end=\"1628\"\u003e\n\n\u003cp data-start=\"1569\" data-end=\"1628\"\u003e Adjustment: T-handle for easy and precise pressure adjustment \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1629\" data-end=\"1690\"\u003e\n\n\u003cp data-start=\"1631\" data-end=\"1643\"\u003e Manometers: \u003c\/p\u003e\n\n\u003cul data-start=\"1646\" data-end=\"1690\"\u003e\n\n\u003cli data-start=\"1646\" data-end=\"1690\"\u003e\n\n\u003cp data-start=\"1648\" data-end=\"1690\"\u003e 63 mm (2 1\/2\") pressure gauges with protection \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1691\" data-end=\"1740\"\u003e\n\n\u003cp data-start=\"1693\" data-end=\"1714\"\u003e High pressure manometer: \u003c\/p\u003e\n\n\u003cul data-start=\"1717\" data-end=\"1740\"\u003e\n\n\u003cli data-start=\"1717\" data-end=\"1740\"\u003e\n\n\u003cp data-start=\"1719\" data-end=\"1740\"\u003e 4400 psig (300 bar) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1741\" data-end=\"1789\"\u003e\n\n \u003cp data-start=\"1743\" data-end=\"1764\"\u003eLow pressure manometer: \u003c\/p\u003e\n\n\u003cul data-start=\"1767\" data-end=\"1789\"\u003e\n\n\u003cli data-start=\"1767\" data-end=\"1789\"\u003e\n\n\u003cp data-start=\"1769\" data-end=\"1789\"\u003e 1000 psig (70 bar) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"1791\" data-end=\"1794\"\u003e\n\n\u003ch3 data-start=\"1796\" data-end=\"1812\"\u003e Areas of application \u003c\/h3\u003e\n\n\u003cul data-start=\"1814\" data-end=\"1957\"\u003e\n\n\u003cli data-start=\"1814\" data-end=\"1850\"\u003e\n\n\u003cp data-start=\"1816\" data-end=\"1850\"\u003e Leak testing of HVAC systems \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1851\" data-end=\"1877\"\u003e\n\n\u003cp data-start=\"1853\" data-end=\"1877\"\u003e Automotive AC systems \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1878\" data-end=\"1915\"\u003e\n\n\u003cp data-start=\"1880\" data-end=\"1915\"\u003e Refrigeration systems for R12, R22 and R134a \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1916\" data-end=\"1957\"\u003e\n\n\u003cp data-start=\"1918\" data-end=\"1957\"\u003e All systems with 1\/4\" SAE connection\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Min butikk","offers":[{"title":"Default Title","offer_id":51709858677037,"sku":"53006","price":2900.0,"currency_code":"NOK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0932\/4668\/5485\/files\/53002-web.jpg?v=1769449266","url":"https:\/\/shop.autoclima.no\/en\/products\/nitrogenregulator-mastercool","provider":"Autoclima AS","version":"1.0","type":"link"}