{"product_id":"90063-2v-110-bl-black-series-3-cfm-vacuum-pump-two-stage","title":"Electronic leak detector for refrigerants and flammable gases","description":"\u003cp data-start=\"137\" data-end=\"226\"\u003e \u003cstrong data-start=\"137\" data-end=\"226\"\u003eIntellasense 55800 – Electronic leak detector for refrigerants and flammable gases\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp data-start=\"228\" data-end=\"281\"\u003e A highly sensitive leak detector for professional use\u003c\/p\u003e\n\n \u003cp data-start=\"283\" data-end=\"707\"\u003eThe Mastercool Intellasense 55800 is an advanced leak detector designed to detect even the smallest amounts of refrigerants and flammable gases. It uses a newly developed metal oxide sensor with high sensitivity and lightning-fast response. An integrated microprocessor optimizes the sensor's performance in real time, ensuring reliable detection under all conditions. The device is approved according to J2791 (R134a), J2913 (R1234yf) and EN 14624.\u003c\/p\u003e\n\n\u003chr data-start=\"709\" data-end=\"712\"\u003e\n\n\u003cp data-start=\"714\" data-end=\"733\"\u003e \u003cstrong data-start=\"714\" data-end=\"733\"\u003eSpecifications\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"735\" data-end=\"1374\"\u003e\n\n\u003cli data-start=\"735\" data-end=\"862\"\u003e\n\n\u003cp data-start=\"737\" data-end=\"754\"\u003e \u003cstrong data-start=\"737\" data-end=\"752\"\u003eDetects:\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"757\" data-end=\"862\"\u003e\n\n\u003cli data-start=\"757\" data-end=\"796\"\u003e\n\n\u003cp data-start=\"759\" data-end=\"796\"\u003e All CFC, HCFC and HFC refrigerants \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"799\" data-end=\"824\"\u003e\n\n\u003cp data-start=\"801\" data-end=\"824\"\u003e R1234yf, R32 and R410A \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"827\" data-end=\"839\"\u003e\n\n\u003cp data-start=\"829\" data-end=\"839\"\u003e Hydrogen \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"842\" data-end=\"862\"\u003e\n\n\u003cp data-start=\"844\" data-end=\"862\"\u003e Flammable gases\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"864\" data-end=\"997\"\u003e\n\n\u003cp data-start=\"866\" data-end=\"892\"\u003e \u003cstrong data-start=\"866\" data-end=\"890\"\u003eSensitivity levels:\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"895\" data-end=\"997\"\u003e\n\n\u003cli data-start=\"895\" data-end=\"928\"\u003e\n\n\u003cp data-start=\"897\" data-end=\"928\"\u003e High: ≥ 4.25 g\/yr (0.15 oz\/yr) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"931\" data-end=\"964\"\u003e\n\n\u003cp data-start=\"933\" data-end=\"964\"\u003e Medium: ≥ 7 g\/yr (0.25 oz\/yr) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"967\" data-end=\"997\"\u003e\n\n\u003cp data-start=\"969\" data-end=\"997\"\u003e Low: ≥ 14 g\/yr (0.5 oz\/yr) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"999\" data-end=\"1036\"\u003e\n\n\u003cp data-start=\"1001\" data-end=\"1036\"\u003e \u003cstrong data-start=\"1001\" data-end=\"1019\"\u003eSensor life:\u003c\/strong\u003e Approx. 2000 hours \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1037\" data-end=\"1097\"\u003e\n\n\u003cp data-start=\"1039\" data-end=\"1097\"\u003e \u003cstrong data-start=\"1039\" data-end=\"1060\"\u003eOperating Temperature:\u003c\/strong\u003e 0°F to 140°F (–18°C to 60°C)\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1098\" data-end=\"1152\"\u003e\n\n \u003cp data-start=\"1100\" data-end=\"1152\"\u003e\u003cstrong data-start=\"1100\" data-end=\"1119\"\u003ePower supply:\u003c\/strong\u003e 2 x D batteries (included) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1153\" data-end=\"1207\"\u003e\n\n\u003cp data-start=\"1155\" data-end=\"1207\"\u003e \u003cstrong data-start=\"1155\" data-end=\"1170\"\u003eBattery life:\u003c\/strong\u003e Approximately 60 hours of continuous use \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1208\" data-end=\"1240\"\u003e\n\n\u003cp data-start=\"1210\" data-end=\"1240\"\u003e \u003cstrong data-start=\"1210\" data-end=\"1219\"\u003eWeight:\u003c\/strong\u003e 680g (1lb. 8oz) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1241\" data-end=\"1374\"\u003e\n\n\u003cp data-start=\"1243\" data-end=\"1255\"\u003e \u003cstrong data-start=\"1243\" data-end=\"1253\"\u003eProbe:\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"1258\" data-end=\"1374\"\u003e\n\n\u003cli data-start=\"1258\" data-end=\"1293\"\u003e\n\n\u003cp data-start=\"1260\" data-end=\"1293\"\u003e 39.5 cm (15.5\") flexible probe \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1296\" data-end=\"1374\"\u003e\n\n\u003cp data-start=\"1298\" data-end=\"1374\"\u003e Intelligent tip that adapts to the environment and minimizes false alarms \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"1376\" data-end=\"1379\"\u003e\n\n\u003cp data-start=\"1381\" data-end=\"1407\"\u003e \u003cstrong data-start=\"1381\" data-end=\"1407\"\u003eDisplay and indicators\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"1409\" data-end=\"1690\"\u003e\n\n\u003cli data-start=\"1409\" data-end=\"1481\"\u003e\n\n\u003cp data-start=\"1411\" data-end=\"1481\"\u003e Backlit LCD display with 10 level leak strength indicators \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1482\" data-end=\"1534\"\u003e\n\n\u003cp data-start=\"1484\" data-end=\"1534\"\u003e Displays selected sensitivity level (High, Medium, Low) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1535\" data-end=\"1573\"\u003e\n\n\u003cp data-start=\"1537\" data-end=\"1573\"\u003e Low battery symbol \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1574\" data-end=\"1639\"\u003e\n\n\u003cp data-start=\"1576\" data-end=\"1639\"\u003e “READY”, “WAIT” and “INT” are displayed when status changes or errors occur \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1640\" data-end=\"1690\"\u003e\n\n\u003cp data-start=\"1642\" data-end=\"1690\"\u003e Error codes: E1–E9 display diagnostic information \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"1692\" data-end=\"1695\"\u003e\n\n\u003cp data-start=\"1697\" data-end=\"1724\"\u003e \u003cstrong data-start=\"1697\" data-end=\"1724\"\u003eFunctions and operation\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"1726\" data-end=\"2172\"\u003e\n\n\u003cli data-start=\"1726\" data-end=\"1804\"\u003e\n\n\u003cp data-start=\"1728\" data-end=\"1804\"\u003e Automatic optimization of sensor performance via integrated microprocessor\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1805\" data-end=\"1900\"\u003e\n\n \u003cp data-start=\"1807\" data-end=\"1900\"\u003e“Super Sensitive” function for detecting very small leaks (e.g. R1234yf and R407C) \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1901\" data-end=\"2172\"\u003e\n\n\u003cp data-start=\"1903\" data-end=\"1916\"\u003e \u003cstrong data-start=\"1903\" data-end=\"1914\"\u003eKeys:\u003c\/strong\u003e \u003c\/p\u003e\n\n\u003cul data-start=\"1919\" data-end=\"2172\"\u003e\n\n\u003cli data-start=\"1919\" data-end=\"1953\"\u003e\n\n\u003cp data-start=\"1921\" data-end=\"1953\"\u003e \u003cstrong data-start=\"1921\" data-end=\"1932\"\u003eON\/OFF:\u003c\/strong\u003e Turns the device on\/off \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1956\" data-end=\"2008\"\u003e\n\n\u003cp data-start=\"1958\" data-end=\"2008\"\u003e \u003cstrong data-start=\"1958\" data-end=\"1974\"\u003eVOLUME\/MUTE:\u003c\/strong\u003e Adjusts or mutes the sound level \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2011\" data-end=\"2055\"\u003e\n\n\u003cp data-start=\"2013\" data-end=\"2055\"\u003e \u003cstrong data-start=\"2013\" data-end=\"2023\"\u003eH\/M\/L:\u003c\/strong\u003e Select the desired sensitivity level \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2058\" data-end=\"2110\"\u003e\n\n\u003cp data-start=\"2060\" data-end=\"2110\"\u003e \u003cstrong data-start=\"2060\" data-end=\"2069\"\u003eHOLD:\u003c\/strong\u003e Freezes the leak level for easy reading \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2113\" data-end=\"2172\"\u003e\n\n\u003cp data-start=\"2115\" data-end=\"2172\"\u003e \u003cstrong data-start=\"2115\" data-end=\"2124\"\u003ePEAK:\u003c\/strong\u003e Used when searching for multiple leaks at the same time\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Min butikk","offers":[{"title":"Default Title","offer_id":51623924367661,"sku":"'20","price":4550.0,"currency_code":"NOK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0932\/4668\/5485\/files\/55975_web_8eacbc27-bd5e-4114-94f4-e7b5dda974b3.jpg?v=1766272178","url":"https:\/\/shop.autoclima.no\/en\/products\/90063-2v-110-bl-black-series-3-cfm-vacuum-pump-two-stage","provider":"Autoclima AS","version":"1.0","type":"link"}